Back to store
Stager FD 3600ER Automatic single-phase power Generator, 230V, 3.0kW, petrol, ATS connector, multistart, runtime up to 20h

Stager FD 3600ER Automatic single-phase power Generator, 230V, 3.0kW, petrol, ATS connector, multistart, runtime up to 20h

-20% Black Friday
5028.76 RON 4023.01 RONVAT included
Lowest price in the last 30 days: 5028.76 RON
Site stock100
In stock · Delivery is calculated at checkout.
Estimated shipping cost Easybox (Sameday) 9.99 RON Romania, to your address 29.99 RON Hungary, Bulgaria or Greece 49.99 RON
Shipping is calculated transparently before order submission Returns follow the store policy available in the legal pages Payment by card, bank transfer or cash on delivery when available

Description:The FD 3600ER automatic generator is a single-phase power supply unit, suitable for both domestic and professional use. With a maximum power of 3.0kW and numerous starting options, including automatic start via ATS (external automation unit), the generator is built to ensure continuity of supply in an emergency. The multistart system and the dedicated connector for integration with solar inverters or other automation systems make it an ideal solution for a wide range of off-grid and backup applications.
Multiple starting methods The Stager FD 3600ER automatic generator offers various starting options to ensure flexibility and adaptability in operation: Manual start via recoil starter. Electric key start. Remote start via radio remote control. Automatic start when the mains supply is interrupted, managed by an external ATS unit, which switches the supply to the generator until electric power is restored. Remote-controlled start via cable, using a dedicated connector. Starting and stopping are done via an external contact, configured as follows: NC (Normally Closed) for generator running and NO (Normally Open) for generator stopped. This functionality allows the generator to be integrated into off-grid photovoltaic systems, for automatic charging of the batteries when necessary, and can be adapted for various other automation systems. To select the desired starting mode, the generator is equipped with a button on the panel, marked “ON / OFF / ECO” (note: “ECO” does not represent an energy-saving function). This button allows the user to choose between three operating modes: • ON position (1): Activates control via the ATS connector. • OFF position (0): Activates control from the remote control, allowing start/stop via radio remote control, as well as manual key start and recoil start. • ECO position (2): Activates control via the remote control connector. This button facilitates the transition between starting modes, giving the user greater versatility in using the generator for different applications.
Easy to transport The standard delivery set of the generator includes a transport kit, consisting of 2 wheels, two support feet and a foldable handle, fitted with a locking pin.
Extended runtime The high-performance engine, equipped with a robotic choke, together with the copper-wound alternator and the 12L fuel tank, ensures an operating time of up to 30 hours. The fuel level indicator integrated into the tank allows a quick check of the available quantity, for efficient management of the supply.
Smart display The new smart display of the Stager generators in the Automatic series shows all the necessary information: voltage, frequency, power and operating hours. The hour-counting function allows precise scheduling of services, for optimal maintenance.
Low oil level protection system The Stager FD 3600ER automatic generator includes a protection system that prevents the engine from running if the oil level drops below the minimum threshold, either by automatic shutdown or by blocking the start. The warning LED tells the user to check and top up with Progarden 10W30 oil, ensuring safe and durable operation.
Complete safety The generator is fitted with automatic circuit breakers for the single-phase and three-phase circuits, as well as an additional thermal fuse that trips in case of overload. It also includes a fuse on the 12V DC circuit, thus ensuring complete protection of the equipment.
Robotic choke Stager generators in the Automatic series are equipped with a robotic (automatic) choke, with precise opening and closing, electrically actuated by a stepper motor. The integrated multifunction controller automatically monitors and adjusts the position of the choke valve, optimising the starting and operation of the generator.
Robust structure and modern design The generator is built in a durable tubular metal frame, electrostatically painted for resistance to scratches and corrosion. The structure is completed with quality plastic elements, which ensure the harmonious integration of the front panel, the tank, the transport kit and the power components.
Sustainability The engine complies with the latest European environmental standards on polluting emissions, ensuring high power and high efficiency.
Vibration damping The engine and alternator are mounted on elastic supports, specially designed to attenuate vibrations, reducing noise, protecting the components and increasing stability during operation.
Easy maintenance The generator is designed for quick and efficient maintenance. Easy access to the air filter allows easy cleaning or replacement, and the oil drain and filling points are ergonomically positioned. The integrated hour counter helps monitor use and schedule periodic services.
Automatic battery charging The generator has a battery charging system, ensuring that it is powered during operation or on standby, when connected to a compatible automation system. This system guarantees the availability of the generator for quick start and automatic operation.
Technical data:GeneratorRated frequency: 50 HzNumber of phases: Single-phasePower factor (cos φ): 1Rated voltage: 230 VRated power: 2.8 kWMaximum power: 3.0 kWRated current: 12.17 AFuel consumption100% load: 1.92 L/h75% load: 1.73 L/h50% load: 1.32 L/h25% load: 0.58 L/hRuntime@100% load: 6.25 hours@75% load: 6.9 hours@50% load: 9.1 hours@25% load: 20.7 hours Structure: Open-frame Net weight: 49 kg Dimensions (L x W x H): 615 × 450 × 485 mm Guaranteed noise level (LwA): 93 dB(A)
Engine: Model: YH170F(E) Engine type: Petrol, single-cylinder, 4-stroke, air-cooled Rated power: 7.5 HP Rated speed: 3000 rpm Bore x stroke: 70 × 54 mm Displacement: 212 cm³ Compression ratio: 8.5 : 1 Oil sump capacity: 0.6 L Oil type: SAE 10W-30 (PRO 10W-30), 5W-30
Fuel tank capacity: 12 L Fuel type: Unleaded petrol Intake system: Naturally aspirated Governor type: Electronic Starting system: - Electric, 12V DC - Recoil starter Battery capacity: 7 Ah
Alternator:Alternator type: single-phase, copper-wound Maximum power: 3.0 kVA Rated speed: 3000 rpm Rated voltage: 230 V Insulation class: H Protection rating: IP23M
Features:2 single-phase 16A sockets, IP44 protection AC automatic fuse AC thermal fuse 12VDC / 8A DC output DC thermal fuse LCD display (frequency, voltage and operating hours) Oil shortage sensor Warning LED for oil level Manual start via recoil starter Electric key start system ON/OFF/START Radio remote control 2-pin external control connector, compatible with external automation systems, OffGrid inverters, etc 3-pin ATS connector (+12V, -12V and control wire), configured for NC=on, NO=off Carburettor with automatic, robotic choke Solid tubular frame, electrostatically painted, for durability and protection Large fuel tank, capacity 22 litres Transport kit with 2 wheels, 2 support feet and foldable handle
Package contents:1 x 12 V battery 1 x Transport wheel set 1 x Key holder with spark plug wrench, screwdriver, 10-12 wrench 2 x Single-phase 16A plug 1 x 2-pin connector for remote control 1 x Oil funnel 1 x Radio remote control 2 x Starting key 1 x User manual

  • ) The state of the generator changes by closing the circuit between pins 1 and 3 of the control connector. During operation the circuit stays permanently closed both in ATS mode and in SOLAR mode (photovoltaic panels).Operation is in a loop. Closing the circuit changes the state of the generator: if it is running, it stops it, and if it is stopped, it starts it.

Optional: **) Stager FDATS230V Solar Automation for single-phase generators, Solar series 2 poles, 50A, 15V DC - 5160000005
Stager FDATS 230-400V Solar Automation for three-phase generators, Solar series 4 poles, 50A, 15V DC - 5160000006

Reviews

No imported reviews for this product.