The UT161 multimeter series is a range of extremely reliable, safe, durable and accurate multimeters, CE certified and suitable for the European market.
The UT161 series of multimeters is a range of extremely reliable, safe, durable and accurate multimeters, which are CE certified and suitable for the European market. The displays of these multimeters are backlit LCDs (dark data on a light background) with a count of ± 6000 (for the UT161B and UT161D) and ± 22000 for the UT161E. The screens have a refresh rate of 2-3 times per second and also contain an analogue bar with 31 segments (UT161B and UT161D) or 41 segments (UT161E). The multimeters measure AC and DC voltages of up to 1000V and are equipped with an audible and visual warning when the maximum voltage / current or temperature values are reached. They allow non-contact detection of wires carrying AC voltage. The package includes a USB cable with an optoelectric converter for data transfer to a computer. The power supply consists of four AAA (R03) batteries and the device switches off automatically after 15 minutes of inactivity (the function can be disabled temporarily). The current inputs are protected by tubular fuses, and the fuses can be tested without opening the device. UT161E True RMS 1000 V digital multimeter. Product parameters: - fully complies with IEC / EN61010-1 and has double insulation - included in category CAT III 1000V - indoor electrical installation including three-phase distribution - included in category CAT IV 600V - electrical installation (safety elements, start of the internal installation) - HTN-type LCD display with a maximum display of ± 22000 - refresh rate for most measurements 3x per second - automatic or manual ranges - automatic polarity indication - AC voltage (alternating current) measuring ranges: 220 mV / 1000 V - AC current measuring ranges: 220 µA / 10 A - DC voltage (direct current) measuring ranges: 220 mV / 1000 V - DC current measuring ranges: 220 µA / 10 A - resistor resistance measuring ranges: 220 Ω / 220 MΩ - capacitor measuring ranges: 22 nF / 220mF - frequency measuring range: 10 Hz / 220 MHz - measurement of the gain (β) of transistors - measurement of the silicon junctions of diodes - line continuity measurement - NCV non-contact voltage detection - high accuracy - TRMS, measurement of the effective values of AC voltages and currents - relative measurement mode - MAX / MIN mode - overrange warning: OL - VFC anti-interference filter - USB cable for transferring the measured values to a computer - protection of the inputs against voltage overload greater than 1000V - protection of the µA and mA current input with a FF600 mA H 1000 V fast fuse, ø6 x 32mm CE - protection of the 10A current input with an FF11A / 1000V ø10 x 38mm CE fast fuse - input impedance in the mV range approx. 1GΩ, in other voltage ranges 10MΩ, - testing of diodes and semiconductor junctions with a voltage of 0 to 3V, test current 1.2mA - power supply of 4 AAA R03 1.5V batteries - low battery indication - automatic switch-off after 15 minutes (idle standby) - Optional Bluetooth adapter for data transfer to a PC - measurement in an electromagnetic field with an intensity of 1V / m with an additional error of 5% is also possible Technical parameters: (accuracy is defined at a temperature of 23 ° C ± 5 ° C and a relative humidity less than or equal to 75%) - DC voltage measurement (the input impedance is approximately 1 GΩ for the mV range, approximately 10MΩ for other ranges ): (range / resolution / accuracy) 220.00 mV / 0.01mV / ± (0.1% + 5) 2.2000 V / 0.1 mV / ± (0.05% + 5) 22.000 V / 1 mV / ± (0.05% + 5) 220.00 V / 10 mV / ± (0.05% + 5) 1000 V / 0.1 V / ± (0.1% + 5) - AC voltage measurement ( input impedance approx. 10MΩ): (range / resolution / accuracy in the range 40Hz to 1kHz / 1kHz to 10kHz / 40Hz to 100kHz (with LPF filter)) 220.00 mV / 0.01 mV / ± (1.0% + 10) / ± (1, 5% + 30) / unspecified 2.2000 V / 0.1 mV / ± (0.8% + 10) / ± (1.2% + 50) / ± (1.2% + 50) 22.000 V / 1 mV / ± (0.8% + 10) / ± (1.2% + 50) / ± (1.8% + 50) 220.00 V / 10 mV / ± (0.8% + 10) / ± (2.0% + 50) / ± (2.0% + 50) 1000 V / 0.1 V / ± (1.2% + 10) / ± (3.0% + 50) / ± (3, 0% + 50) - AC + DC voltage measurement (input impedance approx. 10MΩ): (range / resolution / accuracy) accuracy in the range 40 Hz to 500 Hz 2.2000 V / 0.1 mV / ± (1.8% + 70) 22.000 V / 1 mV / ± (1.8% + 70) 220.00 V / 10 mV / ± (1.8% + 70) 1000 V / 0.1 V / ± (4.0% + 70) Displays the true RMS value - DC current measurement: (range / resolution / accuracy) ) 220.00 µA / 0.01 µA / ± (0.5% + 10) 2200.0 µA / 0.1 µA / ± (0.5% + 10) 22.000 mA / 1 µA / ± (0.5 % + 10) 220.00 mA / 10 µA / ± (0.5% + 10) 20.000 A / 1 mA / ± (1.2% + 50) - AC current measurement: (range / resolution / accuracy) accuracy in the range 40 Hz to 1kHz / accuracy in the range 1kHz to 10kHz) 220.00 µA / 0 , 01 µA / ± (0.8% + 10) / ± (3% + 50) 2200 µA / 0.1 µA / ± (0.8% + 10) / ± (3% + 50) 22 mA / 1 µA / ± (1.2% + 10) / ± (3% + 50) 220 mA / 10 µA / ± (1.2% + 10) / ± (3% + 50) 20 A / 1 mA / ± ( 1.2% + 10) / ± (3% + 50) - Resistance measurement: (range / resolution / accuracy) 220.00 Ω / 0.01 Ω / ± (0.5% + 10) 2.2000 kΩ / 0.1 Ω / ± (0.5% + 10) 22.000 kΩ / 1 Ω / ± (0.5% + 10) 220.00 kΩ / 10 Ω / ± (0.5% + 10) 2.2000 MΩ / 100 Ω / ± (0.8% + 10) 22.000 MΩ / 1 kΩ / ± (1.5% + 10) 220.00 MΩ / 10 kΩ / ± (3.0% + 50) - Capacitor capacitance measurement: (range / resolution / accuracy) 22.000 nF / 1 pF / ± (3.0% + 5) 220.00 nF / 10 pF / ± (3.0% + 5) 2.2000 µF / 100 pF / ± (3.0% + 5) 22.000 µF / 1 nF / ± (3.0% + 5) 220.00 µF / 10 nF / ± (40% + 5) 2.2000 mF / 100 nF / ± (40% + 5) 22.000 mF / 1 µF / ± (10% + 5) 220.00 mF / 10 µF / ± (20% + 5) - Measurement of diodes and semiconductor junctions: the measured value is 0.12 to 2 V and the green LED is lit: the diode is OK , the measured value is less than 0.12 V and the red LED is lit: the diode may be damaged , the normal voltage drop across the silicon junction is 0.500 to 0.800mV voltage resolution during this measurement: 0.001V - Circuit continuity measurement: when the line resistance is ≥70 Ω, an open circuit is indicated, the buzzer does not emit an audible signal and the red indicator light is lit when the line resistance is ≤ 50 Ω, an uninterrupted circuit is indicated, the buzzer emits a continuous signal and the green indicator light is lit, with overload protection: resistance resolution 1000V for this measurement: 0.1 Ω - Frequency measurement, duty cycle: (range / resolution / accuracy) 10 Hz to 220 MHz / 0.01 Hz to 0.01 MHz / ± 0.01% + 5 0.1% to 99.9% / 0.1% / ± (2.0% + 5) General specifications: - operating temperature: 0 ° C - 40 ° C (32 ° F - 104 ° F) - relative humidity: ≤75% at 0 ° C - 30 ° C; ≤50% at 30 ° C - 40 ° C - storage temperature: -10 ° C - 50 ° C (14 ° F - 122 ° F) - operating altitude: ≤2000 m - electromagnetic compatibility: complies with the standards EN61326-1: 2006 and EN61326-2-2: 2006 - dimensions : 186 mm × 89 mm × 49 mm - weight: 400 g - the device complies with the standards: cETLus, CAT III 1000V, CAT IV 600V, double insulation, overload protection with voltage greater than 1000V EN 61326-1: 2013; EN 61326-2-2: 2013 EN 61010-1: 2010; EN 61010-2-030: 2010; EN 61010-2-033: 2012 Complies with the UL STD standards: 61010-1, 61010-2-030 Certified in accordance with CSA STD. C22.2 No. 61010-1, 61010-2-030, 61010-2-033 Package contents: - UT161E multimeter with storage case - gold-plated measuring leads CAT III 1000V / CAT IV 600V - socket adapter for measuring transistors - USB cable for data transfer to PC - fuse F1: 6 x 32 mm FF 600mA H 1000 V (ø6 x 32mm) CE - in the device - fuse F2: 6 x 25 mm FF 11A H 1000 V (ø10 x 38mm) CE - in the device - 4 AAA R03 1.5V batteries
No imported reviews for this product.