Back to store
Stationary battery AGM VRLA 12V 20AH MW

Stationary battery AGM VRLA 12V 20AH MW

Stationary AGM VRLA battery 12V 20AH MW: 20,0 Ah at 20 h discharge, 19,0 Ah at 10 h, 17,0 Ah at 5 h, at 25 °C: 100% capacity, at 20 °C: 100%, at 0 °C: ~85%, at -15 °C: ~65%, after 3 months: ~91% remaining capacity, after 6 months: ~82%, after 12 months: ~64%.

-20% Black Friday
586.22 RON 468.98 RONVAT included
Lowest price in the last 30 days: 586.22 RON
Site stock100
In stock · Delivery is calculated at checkout.
Estimated shipping cost Easybox (Sameday) 9.99 RON Romania, to your address 29.99 RON Hungary, Bulgaria or Greece 49.99 RON
Shipping is calculated transparently before order submission Returns follow the store policy available in the legal pages Payment by card, bank transfer or cash on delivery when available

The 12V20MW battery (usually denoted MW 20-12) is a sealed VRLA/AGM battery from MW Power, with a nominal voltage of 12 V and a capacity of 20 Ah (C20), from the standard MW series, intended in particular for UPS units, alarm systems, emergency lighting, automation systems and moderate cyclic applications (e.g. small off-grid solar systems, light electric vehicles).

Main technical characteristics

Technology: VRLA (Valve Regulated Lead Acid), AGM – sealed, maintenance-free, can be mounted in various positions.
Nominal voltage: 12 V.
Nominal capacity (C20, 25 °C, 10.5 V cut-off):

  • 20.0 Ah at 20 h discharge
  • 19.0 Ah at 10 h
  • 17.0 Ah at 5 h

Cycle life: up to ~500 cycles at ~50% depth of discharge.
Typical uses: UPS units, alarm systems and DSO, emergency lighting, automation systems, small off-grid photovoltaic systems, light electric vehicles (scooters, electric bicycles).
Body dimensions: 181 × 76–77 × 167 mm (L × W × H).
Total height (with terminals): ~167 mm (terminals on the top face).

Terminals: M5 screw on top (T14), screws included.

Charging and performance parameters

Standby/float charging: 13.50–13.80 V at 25 °C.
Cyclic charging: 14.40–15.00 V.
Maximum recommended charging current: 6.2 A (maximum), recommended ~1.8–2.0 A in standard operation.
Maximum discharge current: up to 210 A for 5 seconds (peak, not continuous).
Internal resistance: ~10 mOhm (charged battery).

Influence of temperature on capacity

  • at 25 °C: 100% capacity
  • at 20 °C: 100%
  • at 0 °C: ~85%
  • at -15 °C: ~65%

Self-discharge (at 25 °C)

  • after 3 months: ~91% capacity remaining
  • after 6 months: ~82%
  • after 12 months: ~64%